APPLY RAIL ASSEMBLY

Check box label.
The following prefixes are provided “factory cut” to size: AL-, 56-, 57-, 58- and 59-.
If cutting is required, continue with step “A”.
If cutting is

not required, proceed to step “B”.

A

Determine rail length dimension “X” by subtract-
ing 1-3/4" from dimension “Y”.

B

TOP VIEW OF EXIT DEVICE

For doors with stile, the rail
must overlap stile by 1/2" or
more

Vertical reference line

(CL of chassis)

1-3/4" min.

“X”

Cut off mark

1. Dog push rail and cut off

at mark.

2. Cut must be straight.
3. For (43-) flush end cap use
cutting guide provided.
4. Remove sharp edges with file.

1. Slide rail assembly over lift arm and onto chassis.
2. Attach rail assembly to chassis with two (2)
#8-32 truss head machine screws.

NOTE: DO NOT tighten screws.


3. Level rail and position mounting plate tight

against rail and attach to door with two (2) #10
round head screws.

4. Tighten all screws securely.

Lift arm

Level

Rail assembly

Rail mounting screw
(2 places) #8-32 x 3/8 ph.
truss head machine screw

Mounting
plate

Mounting plate
screws (#10-24 x
3/4" ph. rd. head
machine screw)

1. Verify rail is not dogged.
2. Screw rod into top case until finger tight.
3. Slide top rod into main slide – do

not pin in place.

4. Attach top case as located in second step.

Through-bolts required and supplied for fire rated top cases on wood doors.

5. Unscrew top rod until the center hole is aligned with the hole in the main slide.
6. Insert rod adjustment pin.

Rod adjustment pin

MOUNT TOP CASE

FIFTH

4

FOURTH

Copyright © 2009-2011, Sargent Manufacturing Company, an ASSA ABLOY Group company.

All rights reserved. Reproduction in whole or in part without the express written permission

of Sargent Manufacturing Company is prohibited.

A6701L

11-30-11