Seventh, Eighth, Ninth – SARGENT HC8700 Hurricane Code Surface Vertical Rod Exit Device User Manual

Page 6: Adjust top & bottom rods, Attach bottom strikes & case

Advertising
background image

SEVENTH

ATTACH STRIKES (Continued)

ELECTRICAL FUNCTION PREFIXES

To access wire channel in door, drill three (3), 1/4" holes in “U”
shaped cutout of mounting bracket.

59- Prefix

Connect switch cable to cable coming from the front of the rail.

Refer to instruction book A7690 for additional wire connections and operating instructions.

AL- Prefix

There are no external wire connections unless used with 546 wiring harness.
Refer to instruction book A7224 for operating instructions.

55- Prefix

Refer to instruction sheet A6808 for wire connections.

56- Prefix

Refer to instruction sheet A6876 for wire connections.

57- Prefix

Refer to instruction sheet A6810 for wire connections and operating instructions.

58- Prefix

Refer to instruction sheet A6835 for wire connections.

1/4” Holes

Mounting

bracket

BOTTOM STRIKES
For thresholds with integral strikes, skip to next step.
For surface applied strikes 624 or 653:
WITH DOOR CLOSED:
1. Transfer vertical centerline to floor or threshold and mark.
2. Engage bottom strike with latchbolt and center on line marked.
3. Mark mounting holes.
4. Drill holes for required fasteners.
5. Mount strike with fasteners provided.
6. Tighten screws securely.
For mortised strikes: 636 or 655
Follow steps above. Mark mounting holes

and outline of strike.

653 Bottom Strike

Alternate Strike for

HC-, 12-, 14-

624 Bottom Strike

(Panic)

1. Fine adjustment is made by turning rod into top and bottom

case to shorten or out of top and bottom case to lengthen.

2. Rough adjustment is made by changing hole used for

adjustment pin.

3. Top Rod Adjustments: Push on door as you push on the rail

assembly. As soon as the door opens, release rail, the top bolt

should be in the hold back position. If not, extend top bolt.

Note: the top bolt must go into hold back position prior to the

door opening.

EIGHTH

ADJUST TOP & BOTTOM RODS

NINTH

2-ISOMETRIC

(2) #12-24 screws

(2) 1/4-20

screws

(3)

#1/4-20

screws

655 Bottom Strike

(HC, 12- & 14-)

4. Bottom Bolt Adjustments: Extend bottom bolt for maximum engagement with the bottom strike. When the top bolt

is in, hold back, it also holds the bottom bolt in the retracted position. Always verify that when the bottom bolt is in

the retracted position, that the bolt clears the finish floor by at least 1/8" through the swing of the door.

Be sure that both top and bottom latch bolts are adjusted for maximum engagement

Copyright © 2009-2011, Sargent Manufacturing Company, an ASSA ABLOY Group company.

All rights reserved. Reproduction in whole or in part without the express written permission

of Sargent Manufacturing Company is prohibited.

A6701L

11-30-11

Steel Screws
and Mortise
Nut

Note: Use two (2) No. 10

steel screws and mortise
nuts (when provided) in
the position illustrated in
the bottom chase. Steel
mortise nuts are twin
knurled for identification.

ATTACH BOTTOM STRIKES & CASE