Meter clean-out, Funnel conversion – Great Plains 3PYPA Operator Manual User Manual

Page 106

Advertising
background image

102

3PYPA

Table of Contents

Index

Great Plains Manufacturing, Inc.

401-647M

Table of Contents

Index

03/20/2012

Refer to Figure 123
8.

If the planter has Y-tubes, shut off the gates at all of
the Y-tubes.

9.

Turn on the air fan and let it run. Use the
“SPLIT AIR -” softkey

a

to reduce the regulated air

pressure to a low value, 1 inch water pressure or
less - this diverts most of the air to the bulk seed
delivery system.

Reduce fan speed as necessary to obtain a low
meter pressurization.

Clean out meters with fan running. Work from one side of
the planter to the other.

Meter Clean-Out

When planting is completed, it is commonly the case that
some seed remains. There may be seed in the hoppers,
hose lines, and meters.

Refer to Figure 124
The planter includes an 817-811C container

for meter

clean-out, stored in a spring-loaded holder at the right
rear of the air manifold. The container can hold all the
seed in the meter and inlet (up to a closed slide gate).

The container can be converted into a true funnel for
complete system clean-out.

Note: The hoppers are connected to the rows with

clamped hose, and are not intended to be routinely
unlatched and tipped for clean-out.

Funnel Conversion
Materials and tools needed:

a length of 1

1

2

in I.D. hose

a worm drive clamp with a working diameter of

approximately 1

1

2

to 2

1

4

in

• a hacksaw

b

with fine-toothed blade

Trim the sump

from the funnel. Slide the hose

fully

onto the funnel tip. Secure with clamp

(do not -over-

tighten clamp, the funnel wall be crushed).

The choice of complete system clean-out process
depends on whether you are using the 817-811C as a
container or funnel.

a. The “FILL METER” function can divert all the air to seed delivery, but only does so for a short period of time (~90 seconds).
b. The funnel wall is thin ABS. Scissor-type pipe-cutting tools may fracture it. Rotary-type pipe cutting tools may slip off.

Null4:

Figure 123

Y-Tube Shut-Off

29758

Null4:

Figure 124

Convert Container to Funnel

29988

1

4

2

3

1

2

3

4

2