Troubleshooting

91

03/20/2012

Table of Contents

Index

401-647M

Null4.aac:

Metadata: End of “Population Too High“

Population Too High

Problem

Cause

Solution

Overall High
Population

Incorrect seed rate

Check seed rate charts

Two seeds per pocket on the disk
(doubles), due to excess meter pres-
surization

Methodically decrease the controlled air to the meter. See
Fan and Adjustment” on page 62.

Two seeds per pocket on the disk
(doubles), due to pockets too large
for the seed

Select a disk with smaller pockets.

Air meter pressure too high due to
pressure sensor not zeroed properly.

Re-zero the air pressure with the fan off. Make sure the dis-
played pressure reads 0.00.

Air pressure too high, false informa-
tion driving the DICKEY-john

®

soft-

ware.

Compare the air pressure reported on the monitor console to
the mechanical gage. If they do not match:
• Inspect the

1

4

in sample lines from the row units up to the

sensor chamber for leaks.

• Make sure all non-planting rows have blank disks.

• Re-zero the air pressure with the fan off.

False alarms or actual seed rate
errors due to monitor setup with
incorrect row count, spacing or
active rows

When troubleshooting population issues, always first rule out
seed monitor setup. Review planter configuration and moni-
tor setup.

Incorrect cell count

Replace seed disks with correct disks, or reset rate for cur-
rent disks (if within range).

Incorrect speed sensor constant

Perform speed calibration per DICKEY-john

®

monitor man-

ual.

Doubles due to incorrect disk for
crop or seed size

Use recommended disk for crop and seed size.

Sticky seeds: excess seed treatment Increase seed lubricant.

Overall High
Population,
cont.

Speed sensor angle.

With planter lowered, check radar speed sensor angle per
DICKEY-john

®

recommendations.

Incorrect speed sensor constant

Perform speed calibration per DICKEY-john

®

monitor man-

ual.

Overlapping passes

Check marker extension (page 164).
For GPS, check planter size programmed.

Actual field size is different

Population may be correct, and calculations are not.

High
Population,
Single Row

Excess meter pressurization causing
doubles

Check shutter.

Worn seed-drop brush and/or strip
brushes allowing excess seed to
pass

Replace worn brushes.

Incorrect seed disk with higher cell
count.

Install correct disk.