Unit-mount cleaner adjustments – Great Plains 3PYPA Operator Manual User Manual

Page 74

Advertising
background image

70

3PYPA

Table of Contents

Index

Great Plains Manufacturing, Inc.

401-647M

Table of Contents

Index

03/20/2012

Unit-Mount Cleaner Adjustments

Refer to Figure 84 and Figure 85
Optional Martin row cleaners are unit-mounted, using:
UMRC: Unit-Mount Row Cleaner (stand-alone), or
UMC-RC: Unit-Mount Coulter RC (on coulter bracket,
with or without a coulter disk present).

There are two adjustments:

1.

Wheel placement (forward or aft mounting hole, for
more or less aggressive cleaning), and

2.

Wheel height, adjusted by a stop. Cleaner arms
float. The stop only sets the lowest position.

In UMRC mount, a pinned cross-tube

on the mount

adjusts the depth. In UMC-RC (coulter) mount, a sliding
down-stop block

adjusts how close to the ground the

row cleaners operate.

The row cleaner needs to be adjusted for your condi-
tions, crop changes, and as coulters and openers wear.
Ideally, cleaners contact only the trash, and do not dis-
turb the soil. If allowed to “dig”, row cleaners can reduce
seed coverage.

Suggested initial depth is tine tips at ground level.

Make the adjustment with the planter raised. Install lift-
assist cylinder locks. Also check bolt

tightness prior to

each planting session, to avoid down-stop slippage.

To adjust the row cleaner:

1.

Determine the height adjustment required. Measure
from the lowest tine to the ground. Determine the
desired new measurement.

2.

Support most or all of the weight of the arm to pre-
vent injury and ease the adjustment. Loosen bolts
on UMC-RC. Remove bent pin

on UMRC.

3.

Support arm at desired height.

4.

UMRC: Slide adjustment tube

until cross-tube

contacts arm at target height. Insert bent pin

in

whichever hole pair is most in alignment.

5.

UMC-RC: Slide the down-stop

on the arm

:

- back toward the pivot for shallower cleaning, or
- forward toward the tines for deeper cleaning.
Tighten the bolts

. Each possible hole pairing

adjusts the tine height by about

3

4

in (19mm).

6.

Check the new height measurement.

Refer to Row Cleaner manual 204-085M-A for further
information on use, adjustment and maintenance of row
cleaners.

Null4:

Sharp Object Hazard:
Wear hand protection when working in this area. Row cleaner
tines, casting edges and coulter blades are sharp.

Figure 84

UMRC: Cleaner Adjust

27308

3

2

1

3

6

5

Null4:

Figure 85

UMC-RC: Row Cleaner Adjust

27343

6

4

5

5

2

1

3

2

6

4

5

Advertising