Steering configuration switch – Great Plains 3PYPA Operator Manual User Manual

Page 33

Advertising
background image

Great Plains Manufacturing, Inc.

Table of Contents

Index

Operating Instructions

29

03/20/2012

Table of Contents

Index

401-647M

Steering Configuration Switch

This cab-mounted switch box controls both normal
operation and field calibration of the steering system. It
has 4 switches and 3 indicator lamps. See page 107 for
calibration details. In normal operations, only the
STEER switch

and indicators

and

are employed.

Steering Control Module Function

Switch Positions and Indications

STEER Toggle Switch:
Steering System Power

On (up): Steering enabled (casters match or float)
Off (down): Steering disabled (casters in Float)

LED:
Power / Fault

On steady: Steering system active (casters match or float)
Blinking: Steering system fault (casters in Float)

FLOAT LED:
Float / Caster

Off: Normal operation - steering system active if STEER on
On: Casters in Float (if STEER LED is steady)

CALIBRATION Toggle Switch:
Calibration Modes

L: Caster aspect sensor (casters in Float)
C: Calibration mode off (normal transport/field mode)
R: Tractor aspect sensor (casters in Float)

LEARN Button:
Calibration (Learn)

First press: Learn tight Right turn
Next press: Learn Straight ahead
Next press: Learn tight Left turn

LED: Calibration

Off: Normal (non-Calibration) operation
Dim: Either Calibration mode selected
Bright Flash: Button

press acknowledged

Rotary Switch Knob
(ONLY APPLIES TO s/n B1027J+)

Vertical position: Normal operation - steering system active while
planting as well as raised
Horizontal position: Used when tractor is utilizing auto-steer -
steering system floats while planting - active only when planter is
raised

1

2

3

1

2

3

4

5

6

5

7

Advertising