LS Closed/PFC Down Pressure Calibration

Tractors with Load Sensing Closed Center Hydraulics
(LS Closed) or Pressure Flow Compensating (PFC) Sys-
tems

Refer to Figure 167
1.

Release locking disk

.

2.

Close bypass valve

for no oil flow by turning

knob

on valve clockwise completely.

3.

Tighten locking disk

.

4.

With tractor at half throttle, adjust flow-control valve
on tractor so openers raise and lower at a reason-
able speed. Keep tractor at one-half throttle for
remaining steps.

Note: Faster opener raise/lower increases potential for oil

over-heating, wear and tractor damage.

5.

Engage tractor hydraulics and lower openers. Lock
hydraulic lever on tractor for continuous operation.

6.

Release locking disks

and

. Adjust pressure-

control valve

knob

for opener down pressure so

gauge

is at 600 psi.

7.

While watching gauge

, slowly turn knob

on

bypass valve

counterclockwise. Adjust bypass

valve

just until needle on gauge

begins to move

down from 600 psi. Use locking disk

to lock

bypass valve at this setting.

Note: The higher the bypass pressure, the greater the po-

tential for oil over-heating and tractor damage.
However, for proper opener operation the bypass
valve must be set at least 300 psi above the opener
down-pressure setting when the tractor is at one-
half throttle. Therefore, you should set the bypass
valve as low as possible while staying at least 300
psi above the opener down pressure setting.

8.

Adjust pressure-control valve

to desired opener

down pressure per “Hydraulic Down Pressure” on
page 60. Tighten loc
king disks

and

.

9.

While 600 psi is a good starting point for setting the
bypass valve, if you consistently operate the planter
with low opener down pressure you can set the
bypass valve below 600 psi. If you consistently oper-
ate the planter with very high opener down pressure,
you may need a bypass-valve setting above 600 psi.

Null4:

Equipment Damage Risk:
Use bypass valve on load-sensing tractors. Failure to use the
bypass valve on load-sensing tractors may cause major tractor
damage.

Figure 167