Great Plains 3PYPA Operator Manual User Manual

Page 94

Advertising
background image

90

3PYPA

Table of Contents

Index

Great Plains Manufacturing, Inc.

401-647M

Table of Contents

Index

03/20/2012

Metadata: End of “Population Too Low“

Low
Population,
One
Section

Clutch slipping, due to contaminants in
clutch, or wear

Lock-up clutch (page 46) until it can be overhauled or
replaced

Skipping chain from drive to section

Check chain slack.
Replace worn chain.

Low
Population,
Single Row

Shutter opening too wide - interfering with
meter pressurization

Adjust shutter to lower setting.

Shutter opening too narrow - starving meter
of seed (low seed pool)

Adjust shutter to higher setting.

Y-tube partially or completely closed, reduc-
ing bulk flow to meter or causing bridging

Open Y-tube for row

Meter starvation due to bridging at shutter

Re-adjust for shutter bridging (page 77).
If seed is treated, increase seed lubricant.

Meter starvation due to bridging above inlet,
caused by low seed delivery air flow

Clear bridge (page 77). Check that seed delivery sys-
tem is getting sufficient fan air, and that there are no
other obstructions upstream.

Meter starvation due to bridging above inlet,
caused by high levels of seed treatment

Clear bridge (page 77). Increase seed lubricant.

Low
Population,
Single
Row, cont.

Skips due to low meter pressurization at one
or several rows

Check shutter setting.
Check for excess wear on seed drop brush.
Check for loose or leaking pressure hose.

Skips due to skipping chain

Check for worn chain, worn idlers, and low chain slack
(page 120).

Skips due to debris in disk pockets

Remove rain covers. Inspect and clean out disks.

Row has blank disk installed

Replace with seeding disk.

Seed sensor obscured

Clean out seed tube (see page 103).

Seed tube plugged

Raise planter, expose bottom of seed tube and clean
out.

Population Too Low

Problem

Cause

Solution

Advertising