Seed Pool Recovery

When a meter has been starved of seed, back-flow of air
through the open shutter reduces delivery air flow. This
causes seed delivery to be slow. If you start or resume
planting with an empty seed pool, the delivery flow may
be too low to keep the meter supplied. The steps below
quickly “prime” the meter by rebuilding the seed pool.

Refer to Figure 119 (which depicts a recovery after an inci-
dence of bridging at air release screen)
1.

Close the shutter

. This stops the air back-flow.

2.

Clear the bridge

or blockage that caused the

meter to run empty.

3.

With the fan running, listen for seed

to fall into the

inlet.

4.

Wait for seed fall

to taper off and stop.

5.

Open the shutter

to the operating setting.

6.

Start or resume planting.

Magnehelic

a

Gauge Troubleshooting

If the Magnehelic® gauge does not read zero with the
fan off, or the reading disagrees with the seed monitor
sensor reading by more than a few tenths of an inch of
water pressure, inspect the gauge, and re-zero as
needed.

Check for chamber and breather line problems before re-
zero. Re-zero cannot accurately compensate for leaks
and blockages.

Re-zero the Magnehelic® gauge on level ground with the
fan off, and if possible, under no-wind conditions. Turn
the set screw

on the meter face until it reads zero from

the tractor driver’s viewing position.

Metadata: End of “Seed Pool Troubleshooting“

a. Magnehelic is a registered trademark of Dwyer Instruments, Inc.

Problem

Cause

Solution

Non-zero
with fan off

Zero drift

Re-zero per instruc-
tions below

Gauge
reading
lower than
sensor

Relief port plug
missing/damaged

Replace plug

Breather line
blocked or kinked

Clear breather line

Leak in sensing
line

Check line to cham-
ber

Gauge damaged

Check for loose
cover, damaged
O-ring

29744

Null4:

Figure 119

Seed Pool Recovery

29744

1

2

3

4

5

1

2

3

4

5

1

Null4:

Figure 120

Magnehelic® Gauge

29842

Port ID for Troubleshooting:

Over-pressure relief port (with plug in place)
Low-pressure port (breather/atmospheric pressure)
High-pressure port (from manifold chamber)

Alternate high/low ports are plugged.

Winter testing/maintenance advisory:
Gauge readings may be inaccurate or sluggish below
20

°F

2
3
4

3

2

4

1