Fertilizer Row Shut-Off

Refer to Figure 75
Fertilizer booms for twin-row planter include caps for
shutting off flow at unused rows. If switching from twin-
row to single-row operation, and applying fertilizer,
replace the drop line nozzles

with 832-042C caps

at unused rows.

The orifice plates

may be removed or left in place.

Adjust pump for new rate. Review orifice size selection
for the new rate. Keep in mind that the row spacing has
changed.

Material Loss Risk:
Do not apply materials without first reviewing setup. Shutting
off rows does not change the application rate. Unless the pump
is reset, it operates at the prior rate, doubling the flow at each
nozzle. This can result in excess pressure, and material loss at
the relief valve.

Null4:

Fertilizer Relief Valve

Refer to Figure 76
When a fertilizer system is installed, a relief valve

and

pressure gauge

are mounted near the fertilizer inlet

at the hitch and provides the fertilizer feed

to the man-

ifold (manifold not shown). The relief valve protects the
manifold, lines and fittings from excessive pressure. Any
product that dumps over the relief valve will discharge
from the dump line

in relative safety.

To set relief valve:

1.

Unlock plastic jam nut

from relief valve knob.

2.

Unscrew knob

clockwise (looking down) until it

loses contact with internal spring.

3.

Screw knob

counterclockwise two turns.

Start at this setting.

4.

Observe manifold gauge

and watch for relief valve

dump line

discharge while operating in the field.

5.

If valve is dumping product and gauge reads under
65 psi, stop tractor and turn knob

clockwise

1

4

turn. Continue operating at normal field speed.

Repeat this step as needed until no product is dis-
charged from relief valve dump line

.

6.

If the pressure gauge reads above 65 psi, change to
a larger orifice. Go to step 2 and repeat.

Null4:

Figure 75

Fertilizer Drop Line Shutoff

29984

Agricultural Chemical Hazard:
Wear protective gloves when
exchanging nozzles and caps.

5

1

2

3

4

3

5

1