Great Plains 1625AHL Operator Manual User Manual

Page 100

Advertising
background image

96

1625AH

Table of Contents

Index

Great Plains Manufacturing, Inc.

411-020M

Table of Contents

Index

2014-04-21

Dry Fertilizer Delivery Troubleshooting

Problem

Cause

Solution

Planter-Wide
Blockage

Material pooling in hose sags or flat runs.

Increase manifold pressure (page 53).

Moisture in hopper has coagulated
material above meter.

Clean-out hopper (page 106).

Out of fertilizer

Add fertilizer.

Single or
multiple hoses
plugging just
ahead of
airbox.

Fan speed too low

Check/adjust fan speed.

Possible air leak

Check for air leak downstream between box and top of
meter.

One or more applicator tines plugged

Clean out tines

1, 2, 3, or more
outlets fail.

Outlets can be
side-by-side or
random.
Plugging may
also move
from one outlet
to another.

Foreign matter in chamber in bottom of
airbox.

Clean out chamber.

Sag in lines

Shorten hoses as necessary to eliminate sags.

Liquid Fertilizer Troubleshooting

Problem

Cause

Solution

No Fertilizer
Flow

Various possible pump issues

Refer to Trouble Chart in CDS-John Blue

®

LM-1250/LM-1255

Parts and Instruction manual, part number 12-M-43.

Discharge and/or main
selector valve closed

Check that discharge valves are open to selector valve, and
selector valve is open to pump. See “Liquid Fertilizer System
(Option)
” on page 56

Chain missing at one or more
drive stages

Check all five chains from ground drive to pump. See “Chain
Routing
” on page 146.

Tank plugged

Dilute or clean out any material clogging discharge port. See
Liquid Fertilizer Clean-Out” on page 110.

Strainer plugged

Close all valves. Inspect strainer (See Seed Rate Manual
(411-020B)). Clean screen as needed. Switch to a larger screen
size if materials clog strainer rapidly (and large size orifices are in
use).

Pump setting at or near zero

Recommended pump adjuster settings are in the range 2 to 10.
See Seed Rate Manual (411-020B).

Material run-out

Check tank level.

Material merely low - loss of
prime

Add material. When tank level is below pump inlet level, any air
allowed in the line can cause the pump to lose prime.

Low Rate

Fertilizer transmission in Low
Range when High Range was
intended.

Swap sprockets at transmission. See Seed Rate Manual
(411-020B).

Various possible pump issues

Refer to Trouble Chart in CDS-John Blue

®

LM-1250/LM-1255

Parts and Instruction manual, part number 12-M-43.

Advertising
This manual is related to the following products: