Setting material rates, Planting (seed) rate – Great Plains 1625AHL Operator Manual User Manual

Page 70

Advertising
background image

66

1625AH

Table of Contents

Index

Great Plains Manufacturing, Inc.

411-020M

Table of Contents

Index

2014-04-21

Setting Material Rates

Refer to Figure 49, which depicts a model 1625AHD
The 1625AH has three ground drive systems:

A. Seed metering, powered by a ground drive system

on each wing.

B. Fertilizer metering, powered by either a cart ground

drive (dry) or a wing ground drive (liquid, not shown).

Details for rate settings, and rate charts, are found in the
Seed Rate Manual (411-020B).

Planting (Seed) Rate

Seed rate is controlled by Range and Transmission
sprocket pairings on each wing ground drive system, and
seed meter setup at each row. The seed monitor console
reports field rates for most seed types.

1. Rate: Monitor configuration:
The seed monitor must be set up with the

• correct row count,

• correct row spacing,

• speed calibration and;

• expected population limits, in order to have accurately

rate reports and useful alarms.

See the Seed Rate Manual (411-020B) and the
DICKEY-john

®

IntelliAg

®

MVT Manual or DICKEY-john

®

PM400 Console Manual.

If you only plant with the factory configuration of the
planter, you never need to update row count and
spacing. If any rows are unused, adjust the monitor
setup.

Speed calibration must be done prior to first use, and
re-calibration is recommended periodically, particularly if
soil conditions change.

2. Rate: Disk Selection:
The Seed Rate Manual (411-020B) has a table of
recommended disks. Disks are specific to crops. Some
crops have multiple disks available, to cover both seed
varieties, and different populations within disk rpm limits.
Disks have high and low rpm limits, which also
correspond to a high and low field speed limits. The
charts account for these limits.

See “Air-Pro

®

Meter Disk Installation” on page 81.

If any rows are unused, install special blank disks. See
Row Unit Shut-Off” on page 83.

3. Rate: Range Sprockets
See Seed Rate Manual

4. Rate: Transmission Sprockets
See Seed Rate Manual

5. Rate: Seed Inlet Shutter
See Seed Rate Manual

6. Rate: Meter Pressurization
See Seed Rate Manual for initial setting, and “Fan
General Operating Information
” on page 53.

7. Rate: Checking
See Seed Rate Manual.

Figure 49

Planter Drive Systems

36166

Figure 50

Typical Monitor Setup Screens

36108
36234

Advertising
This manual is related to the following products: