Magnehelic® gauge troubleshooting, Magnehelic – Great Plains 1625AHL Operator Manual User Manual

Page 94

Advertising
background image

90

1625AH

Table of Contents

Index

Great Plains Manufacturing, Inc.

411-020M

Table of Contents

Index

2014-04-21

Magnehelic

®

Gauge Troubleshooting

If the Magnehelic

®

gauge does not read zero with the fan

off, inspect the gauge, and re-zero as needed.

Check for chamber and breather line problems before
re-zero. Re-zero cannot accurately compensate for leaks
and blockages.

Re-zero the Magnehelic

®

gauge on level ground with the

fan off, and if possible, under no-wind conditions. Turn
the set screw

on the meter face until it reads zero from

the tractor driver’s viewing position.

Problem

Cause

Solution

Non-zero
with fan off

Zero drift

Re-zero per
instructions below

Gauge
reading
lower than
sensor

Relief port plug
missing/damaged

Replace plug

Breather line
blocked or kinked

Clear breather line

Leak in sensing
line

Check line to
chamber

Gauge damaged

Check for loose
cover, damaged
O-ring

1

Figure 97

Magnehelic

®

Gauge

29842

Port ID for Troubleshooting:

Over-pressure relief port (with plug in place)

Low-pressure port (breather/atmospheric pressure)
High-pressure port (from manifold chamber)

Alternate high/low ports are plugged.

Winter testing/maintenance advisory:
Gauge readings may be inaccurate or sluggish below
-7

°C (+20°F)

2
3
4

3

2

4

1

Advertising
This manual is related to the following products: