Seed pool troubleshooting – Great Plains 1625AHL Operator Manual User Manual

Page 93

Advertising
background image

Great Plains Manufacturing, Inc.

Table of Contents

Index

Troubleshooting

89

2014-04-21

Table of Contents

Index

411-020M

Seed Pool Troubleshooting

Figure 96

Rear Cross-Section of Air-Pro

®

Meter in Normal and Row-Failed Conditions

36255

Normal: Filled

Bridging: Inlet Shutter

Bridging: Inlet Tube

Empty Hopper

Inlet is filled to seed hopper.
Seed move slowly down as
singulated by meter.

A bridge at the shutter is
blocking flow.

Causes may include:

• oversize seed

• shutter setting too low

• oversize matter in seed

• excessive or sticky seed

treatment

Oversize matter in seed has
caused a bridge at the top of
the inlet.

Causes may include:

• oversize seed

• oversize matter in seed

• excessive or sticky seed

treatment

No seed arriving from
hopper. Cause is:

• seed run-out

If hopper is empty, air
back-flow

is also

occurring, which can reduce
meter pressurization at other
rows

Actions:

Actions:

Actions:

Actions:

No action required.

Continue Planting.

1.

If shutter was at
suggested opening,
increase one notch.

2.

Check seed pool for
foreign matter.

3.

Resume planting.

1.

Close shutter.

2.

Tap on hopper/tube
junction.

3.

Check seed pool for
foreign matter.

4.

Resume planting.

1.

If row is active,
add seed or check slide
gate.

2.

If row is inactive,
close shutter.

3.

Resume planting.

1

1

Advertising
This manual is related to the following products: