Meter clean-out, Alternate meter clean-out, Seed tube clean-out – Great Plains 1625AHL Operator Manual User Manual

Page 108: Alternate meter clean-out seed tube clean-out

Advertising
background image

104

1625AH

Table of Contents

Index

Great Plains Manufacturing, Inc.

411-020M

Table of Contents

Index

2014-04-21

Meter Clean-Out

Refer to Figure 103
The 817-811C seed collection accessory (funnel

) may

be attached to the housing of the seed meter, freeing
your hands for other tasks during clean-out.

Note: The funnel may not fit rows to the left of ground

drives on twin-row planters. Use vacuum or tarp
collection on those rows.

Note: It may be necessary to raise a twin-row planter to

obtain clearance for the funnel. Use transport locks
(page 24) if the planter is raised.

1.

Close the seed inlet shutter on the meter (page 79).
This minimizes the seed volume at disk removal.

2.

Remove the rain cover (page 79). The funnel cannot
be snapped in place with the cover installed.

3.

Align the left (rear) end of the funnel lip

with the

top of the lower (rear) cover latch ear. Place the right
(front) end of the funnel lip

between the meter

housing and the seed tube.

4.

Rotate the funnel forward until the slot at lip center
engages a tab on the bottom center of the meter
housing.

5.

Remove the seed (page 82).

6.

Slowly open the seed shutter (page 79) to empty the
seed up to the slide gate.

7.

If seed remains in the hopper, use the slide gate to
control the volume of flow.

Refer to Figure 102
8.

Clean seed from all brushes (shop vac
recommended).

9.

Inspect brushes (page 112).

10. Rotate funnel clockwise, remove and empty.

11. For imminent operations:

Install next seed wheel or blank disk (page 83) for
operations. Set inlet shutter for next seed (page 79).

12. For storage:

Close seed inlet shutter. Leave disk out.

13. Re-install rain cover (page 79).

At end-of-season clean-out, inspect a few seed meter air
release screens. If they require cleaning, consider
cleaning all rows.

Seed Tube Clean-Out
The seed sensor in the seed tube can be obscured by
build-up of dust, dirt and seed treatments. This can
cause false low population alarms.

The planter incudes a seed tube brush (Great Plains part
number 891-259C). If the seed meter is empty, remove
the seed disc and insert the brush into the seed tube
from above. With the planter raised, you can also insert
the brush from below, whether the meter is empty or not.

Figure 102

Brush Inspection

29608

5

6

7

1

Alternate Meter Clean-Out
To use a shop vacuum cleaner, with narrow hose nozzle,
to clean out a meter:

• Close the seed shutter.

• Release the meter clamp, hold the disk against the

meter.

• Tip the top of the disk away from the meter.

• Insert hose nozzle and remove seed.

• Open shutter to allow seeds in inlet and drop hose to

flow to vac nozzle.

3

4

Figure 103

Funnel Positioned and Engaged

29612

1

2

3

4

4

Advertising
This manual is related to the following products: