ADS Environmental Services FlowShark QR 775002 A4 User Manual
Page 116

Communication
4-35
Conduit Mount the stub antenna to the end of a section of
conduit as follows:
Obtain a section of conduit with a 5/8-inch (or slightly
greater) internal diameter.
Determine the appropriate length of conduit required.
Route the antenna cable through the conduit, and attach the
large male N-type connector from the antenna cable to the
threaded stud on the antenna.
Use rubber stretch tape and sealer to attach and secure the
antenna to the conduit.
Raise the conduit to the required height, and secure it to
the side of the manhole or wall using off-the-shelf clamps
or fittings.
Run the other end of the cable to the monitor, and attach
the connector to the RADIO port on top of the monitor.
Note: If the antenna cable has the SMA connector, first
attach the SMA-to-TNC adaptor (ADS p/n 507173) to the
RADIO connector port on the monitor and then attach the
cable connector to the adaptor.
Wrap rubber stretch tape around the entire cable
connection, extending onto the cable approximately 2
inches beyond the connection.
Antenna Mast Mount the stub antenna to an antenna mast as
follows:
Attach the large male N-type connector from the antenna
cable to the threaded stud on the stub antenna.
Use rubber stretch tape and sealer to secure the
connection.
Secure the antenna to the mast using clamps or other
applicable hardware.
Run the other end of the cable to the monitor, and attach
the connector to the RADIO port on top of the monitor.