7-2

ADS FlowShark Manual

Warning: Leaving a wireless monitor without an antenna
connected to the monitor will quickly drain the monitor (or
radio) battery packs.

FlowShark antenna connector cap

Note: When temporarily installing a wireless FlowShark
monitor without an antenna, designate Serial for the
Communication Type through the Diagnostics tool in
Profile

®

and use a Y-cable for power (ADS p/n 5000-

0559). This will double the battery life because both
battery packs will be working in parallel to power the
monitor. Refer to Chapter 10, Maintenance and
Troubleshooting
, for information on accessing the battery
pack corresponding to the radio. The Y-cable is applicable
only to earlier versions of the FlowShark monitor and the
current version of Model 5000-BG monitors. All newer
monitors equipped with the combined DSP/
communication board contain battery packs that function
in parallel.