Sensor Installation and Connection 3-31

Securing the other end of the band

Note: If the plate has too much play, attach another
anchor bolt approximately 1 inch from the plate.

10. Slide the ultrasonic plate along the metal band until it is level

(from side to side) with the flow surface and pipe crown, and
tighten the nuts securely with a nut driver. Refer to the
illustration Leveling the Ultrasonic Depth Sensor on page 3-24.

11. Slide the ultrasonic depth sensor into position from the

upstream end of the ultrasonic plate until the back of the sensor
comes in contact with the backstop.

Sliding the ultrasonic depth sensor into place

12. Confirm the ultrasonic depth sensor is still level.