Configuration and Activation 6-23

3. Select or enter the communication parameters as necessary:

Modem Name Select the modem you want to use during

modem communication from the drop-down list. This list
should include all available modems on your computer.

Modem Port Select the proper port for modem

communication from this drop-down list. This list should
include all available ports on your computer.

Serial Port Select the proper port for serial

communication from this drop-down list. This list should
include all available ports on your computer.

DMI Port Select the proper port for communication using

the DMI from this drop-down list. This list should include
all available ports on your computer.

Timeout Enter the number of seconds you want your

local computer to wait for a response from the monitor
once communication has been initiated.

Attempts Enter the number of times you want your local

PC to request data from the monitor following failed
attempts while the monitor is still on line.

Low Temperature Enter the temperature reading from

the monitor, ultrasonic depth sensor, and pressure depth
sensor below which you want Profile to provide
notification.

High Temperature Enter the temperature reading from

the monitor, ultrasonic depth sensor, and pressure depth
sensor above which you want Profile to provide
notification.

Log Communications Select this checkbox to record

all communication activities with the monitor.

Status On Connect Select this checkbox to view

details concerning the current state of the monitor once
communication with the monitor has been established.

Low Battery 1502, 1506, 3500, 4000 (These

parameters do not apply to the FlowShark monitor)