ADS Environmental Services FlowShark QR 775002 A4 User Manual

Page 218

Advertising
background image

10-6

ADS FlowShark Manual

Note: The only service or maintenance activity ADS
permits within the monitor chassis is battery pack
replacement. Therefore, please do not handle, alter,
modify, remove, or replace any other components inside
the monitor. This may void the monitor warranty
agreement.

1. Collect the data from the monitor.

2. Loosen bolts and remove the monitor lid with chassis from the

aluminum canister.

Note: Removing the monitor chassis during battery pack
replacement increases the risk of damaging internal
components or introducing debris or moisture to the
monitor electronics. Make every effort to prevent water,
dirt, and debris from contacting the monitor's internal
components during routine maintenance.

3. Release the Velcro straps securing the battery packs at the

bottom of the chassis.

4. Disconnect the wires connecting the battery packs to the

monitor chassis.

Disconnecting the wiring between the battery packs and the monitor

5. Remove the battery packs from the chassis.