Troubleshooting an internal usb key, Troubleshooting an internal – Dell PowerEdge R815 User Manual

Page 165

Advertising
background image

Troubleshooting Your System

161

25 As the system boots, observe any error message that appears and the

diagnostic indicators on the front of the system.

26 If the memory problem is still indicated, repeat step 16 through step 23 for

each memory module installed.
If the problem persists after all memory modules have been checked, see

"Getting Help" on page 185.

Troubleshooting an Internal USB Key

CAUTION:

Many repairs may only be done by a certified service technician. You

should only perform troubleshooting and simple repairs as authorized in your
product documentation, or as directed by the online or telephone service and
support team. Damage due to servicing that is not authorized by Dell is not covered
by your warranty. Read and follow the safety instructions that came with the
product.

1 Enter the System Setup program and ensure that the internal USB key

port is enabled. See "Integrated Devices Screen" on page 60.

2 Turn off the system and attached peripherals, and disconnect the system

from the electrical outlet.

3 Open the system. See "Opening the System" on page 76.
4 If applicable, move the front chassis assembly. See "Front-Chassis

Assembly" on page 90.

5 If applicable, remove the cooling shroud. See "Removing the Cooling

Shroud" on page 88.

6 Locate the USB key and reseat it. See "Internal USB Memory Key" on

page 104.

7 If applicable, replace the cooling shroud. See "Installing the Cooling

Shroud" on page 89.

8 If applicable, slide the front chassis back. See "Front-Chassis Assembly" on

page 90.

9 Close the system. See "Closing the System" on page 77.

10 Turn on the system and attached peripherals and check if the USB key is

functioning.

11 If the problem is not resolved, repeat step 2 and step 3.