Removing lcd status messages – Dell PowerEdge R815 User Manual

Page 23

Advertising
background image

About Your System

23

Removing LCD Status Messages

For faults associated with sensors, such as temperature, voltage, fans, and so

on, the LCD message is automatically removed when that sensor returns to a

normal state. For other faults, you must take action to remove the message

from the display:

• Clear the SEL—You can perform this task remotely, but you will lose the

event history for the system.

• Power cycle—Turn off the system and disconnect it from the electrical

outlet; wait approximately 10 seconds, reconnect the power cable, and

restart the system.

NOTE:

The following LCD status messages are displayed in the Simple format. See

"Setup Menu" on page 16 to select the format in which the messages are displayed.

Table 1-1. LCD Status Messages

Code

Text

Causes

Corrective Actions

E1000 Failsafe

voltage

error.

Contact

support.

Check the system event log

for critical failure events.

Remove AC power to the

system for 10 seconds and

restart the system.
If the problem persists,

see "Getting Help" on

page 185.

E1114 Ambient Temp

exceeds

allowed

range.

Ambient temperature

reached a point outside the

allowed range.

See "Troubleshooting

System Cooling

Problems" on page 157.

E1116 Memory

disabled,

temp above

range. Power

cycle AC.

Memory exceeded allowable

temperature and has been

disabled to prevent damage

to the components.

Remove AC power to the

system for 10 seconds and

restart the system.
See "Troubleshooting

System Cooling

Problems" on page 157. If

the problem persists, see

"Getting Help" on

page 185.

book.book Page 23 Wednesday, December 18, 2013 2:48 PM