Dell PowerEdge R815 User Manual

Page 28

Advertising
background image

28

About Your System

E1620 Power Supply

# (#### W) AC

power error.

Check PSU

cables.

Specified power supply's AC

input is outside the

allowable range.

Check the AC power

source for the specified

power supply. If the

problem persists, see

"Troubleshooting Power

Supplies" on page 157.

E1624 Lost power

supply

redundancy.

Check PSU

cables.

The power supply subsystem

is no longer redundant. If

the remaining power supply

fails, the system will shut

down.

See "Troubleshooting

Power Supplies" on

page 157.

E1629 Power

required >

PSU wattage.

Check PSU and

config.

The system configuration

requires more power than

the power supplies can

provide, even with

throttling.

Turn off power to the

system, check if adequate

power is supplied to the

system. See the Getting

Started Guide for

information on the

System power

requirements.

E1631 System power

draw exceeded

threshold.

Contact

support.

Processor and memory

throttling is not sufficient to

keep system power

consumption below the

maximum safe level with

the current power supply

configuration.

Remove AC power to the

system for 10 seconds and

restart the system.
If the problem persists,

see "Getting Help" on

page 185.

E1632 FailSafe

event.

Contact

support.

The processors and memory

have been throttled to keep

system power consumption

below the maximum safe

level with current power

supply configuration.

Remove AC power to the

system for 10 seconds and

restart the system.
If the problem persists,

see "Getting Help" on

page 185.

Code

Text

Causes

Corrective Actions

book.book Page 28 Wednesday, December 18, 2013 2:48 PM

Advertising