W1100 CPU VCORE

Regulator

temp

exceeding

range. Check

fans.

The regulator temperature

reached a point outside the

allowed range.

See "Troubleshooting

System Cooling

Problems" on page 157. If

the problem persists, see

"Getting Help" on

page 185.

W1102 Mem Voltage

Regulator

temp

exceeding

range. Check

fans

The regulator temperature

reached a point outside the

allowed range.

See "Troubleshooting

System Cooling

Problems" on page 157. If

the problem persists, see

"Getting Help" on

page 185.

W1228 RAID

Controller

battery

capacity <

24hr.

Warns predictively that the

RAID battery has less than

24 hours of charge left.

Allow RAID battery to

charge to greater than 24

hours of sustained charge.
If problem persists,

replace the RAID battery.

See "Internal Dual SD

Module (Optional)" on

page 123.

W1630 Power supply

redundancy

degraded.

Check PSU

cables.

The power supply subsystem

is no longer fully redundant.

Reseat the power supplies.

See "Troubleshooting

Power Supplies" on

page 157.
If the problem persists,

see "Getting Help" on

page 185.

NOTE:

For the full name of an abbreviation or acronym used in this table, see the

Glossary

at support.dell.com/manuals.

Code

Text

Causes

Corrective Actions