Dell PowerEdge R815 User Manual

Page 29

Advertising
background image

About Your System

29

E1710 I/O channel

check error.

Review &

clear SEL.

The system BIOS reported

an I/O channel check.

Check the SEL for more

information and then

clear the SEL. Remove

AC power to the system

for 10 seconds and restart

the system.
If the problem persists,

see "Getting Help" on

page 185.

E1711 PCI parity

error on Bus

## Device ##

Function ##.

The system BIOS reported a

PCI parity error on a

component that resides in

PCI configuration space at

bus ##, device ##,

function ##.

Remove and reseat the

PCIe expansion cards. If

the problem persists, see

"Troubleshooting

Expansion Cards" on

page 166.

PCI parity

error on Slot

#. Review &

clear SEL.

The system BIOS reported a

PCI parity error on a

component that resides in

the specified slot.

Remove and reseat the

PCIe expansion cards. If

the problem persists, see

"Troubleshooting

Expansion Cards" on

page 166.

E1712 PCI system

error on Bus

## Device ##

Function ##.

The system BIOS reported a

PCI system error on a

component that resides in

PCI configuration space at

bus ##, device ##,

function ##.

Remove and reseat the

PCIe expansion cards. If

the problem persists, see

"Troubleshooting

Expansion Cards" on

page 166.

PCI system

error on Slot

#. Review &

clear SEL.

The system BIOS reported a

PCI system error on a

component that resides in

the specified slot.

Remove and reseat the

expansion-card riser that

provides the specified slot.

See "Expansion Cards and

Expansion-Card Risers"

on page 107. If the

problem persists, the riser

card or system board is

faulty. See "Getting Help"

on page 185.

Code

Text

Causes

Corrective Actions

book.book Page 29 Wednesday, December 18, 2013 2:48 PM

Advertising