About Your System

E1414 CPU # temp

exceeding

range. Check

CPU heatsink.

Specified processor is out of

acceptable temperature

range.

Ensure that the processor

heat sinks are properly

installed. See

"Troubleshooting the

Processors" on page 168

and "Troubleshooting

System Cooling

Problems" on page 157.

E1418 CPU # not

detected.

Check CPU is

seated

properly.

Specified processor is

missing or bad and the

system is in an unsupported

configuration.

Ensure that the specified

processor is properly

installed. See

"Troubleshooting the

Processors" on page 168.

E141C Unsupported

CPU

configuration

. Check CPU

or BIOS

revision.

Processors are in an

unsupported configuration.

Ensure that your

processors match and

conform to the type

described in the processor

technical specifications

outlined in your system’s

Getting Started Guide.

E141F CPU #

protocol

error. Power

cycle AC.

The system BIOS reported a

processor protocol error.

Remove AC power to the

system for 10 seconds and

restart the system.
If the problem persists,

see "Getting Help" on

page 185.

E1420 CPU Bus

parity error.

Power cycle

AC.

The system BIOS reported a

processor bus parity error.

Remove AC power to the

system for 10 seconds and

restart the system.
If the problem persists,

see "Getting Help" on

page 185.

Code

Text

Causes

Corrective Actions

book.book Page 26 Wednesday, December 18, 2013 2:48 PM