Cooling shroud, Removing the cooling shroud – Dell PowerEdge R815 User Manual

Page 88

Advertising
background image

88

Installing System Components

Cooling Shroud

The cooling shroud covers the memory modules and provides air flow to the

system.

Removing the Cooling Shroud

CAUTION:

Many repairs may only be done by a certified service technician. You

should only perform troubleshooting and simple repairs as authorized in your
product documentation, or as directed by the online or telephone service and
support team. Damage due to servicing that is not authorized by Dell is not covered
by your warranty. Read and follow the safety instructions that came with the
product.

CAUTION:

Never operate your system with the cooling shroud removed. The

system may get overheated quickly, resulting in shutdown and loss of data.

1 Turn off the system, including any attached peripherals, and disconnect

the system from the electrical outlet.

2 Open the system. See "Opening and Closing the System" on page 76.
3 Remove the RAID battery from the battery carrier. See Figure 3-9.
4 Hold the touch points and gently lift the cooling shroud away from the

system. See Figure 3-9.