25

E122D Memory

Regulator #

Failed.

Reseat DIMMs.

One of the memory voltage

regulators failed.

Reseat the memory

modules. See

"Troubleshooting System

Memory" on page 159.

E122E On-board

regulator

failed. Call

support.

One of the on-board voltage

regulators failed.

Remove AC power to the

system for 10 seconds and

restart the system.
If the problem persists,

see "Getting Help" on

page 185.

E1243 CPU # VCORE

Regulator

failure.

Contact

Support.

Processor voltage regulator

failed.

Reseat the processor. See

"Troubleshooting the

Processors" on page 168.
If the problem persists,

see "Getting Help" on

page 185.

E1310 Fan ## RPM

exceeding

range. Check

fan.

RPM of specified fan is

outside the intended

operating range.

See "Troubleshooting

System Cooling

Problems" on page 157.

E1313 Fan

redundancy

lost. Check

fans.

The system is no longer fan

redundant. Another fan

failure would put the system

at risk of over-heating.

Check LCD for additional

scrolling messages. See

"Troubleshooting a Fan"

on page 158.

E1314 Critical

system

cooling loss.

Check fans.

All fans have been removed

from the system.

Ensure that the fans are

properly installed. See

"Troubleshooting a Fan"

on page 158.

E1410 System Fatal

Error

detected.

A fatal system error

detected.

Check LCD for additional

scrolling messages.

Remove AC power to the

system for 10 seconds and

restart the system.
If the problem persists,

see "Getting Help" on

page 185.

Code

Text

Causes

Corrective Actions