About Your System

The amount of

system memory has

changed.

Memory has been added or

removed or a memory

module may be faulty.

If memory has been added or

removed, this message is

informative and can be

ignored. If memory has not

been added or removed,

check the SEL to determine

if single-bit or multi-bit

errors were detected and

replace the faulty memory

module. See

"Troubleshooting System

Memory" on page 159.

Time-of-day

clock stopped.

Faulty battery or faulty chip. See "Troubleshooting the

System Battery" on page 156.

Time-of-day not

set - please run

SETUP program.

Incorrect Time or Date

settings; faulty system

battery.

Check the Time and Date

settings. See "Using the

System Setup Program and

UEFI Boot Manager" on

page 53. If the problem

persists, replace the system

battery. See "System Battery"

on page 131.

Timer chip

counter 2 failed.

Faulty system board.

See "Getting Help" on

page 185.

TPM or TCM

configuration

operation

honored. System

will now reset.

A Trusted Platform Module

(TPM) or China Trusted

Platform Module (TCM)

configuration command has

been entered. The system

will reboot and execute the

command.

Information only.

Message

Causes

Corrective Actions