Dell PowerEdge R815 User Manual

Page 41

Advertising
background image

About Your System

41

CPUs with

different cache

sizes detected.

Mismatched processors have

been installed in the system.

Ensure that all processors

have the same cache size,

number of cores, and power

rating. Ensure that the

processors are properly

installed. See "Processors" on

page 125.

CPUs with

different core

sizes detected!

System halted.

CPUs with

different power

rating detected!

System halted.

Current boot mode

is set to UEFI.

Please ensure

compatible

bootable media is

available. Use

the system setup

program to change

the boot mode as

needed.

The system failed to boot

because UEFI boot mode is

enabled in BIOS and the

boot operating system is non-

UEFI.

Ensure that the boot mode is

set correctly and that the

proper bootable media is

available. See "Using the

System Setup Program and

UEFI Boot Manager" on

page 53.

Decreasing

available

memory.

Faulty or improperly installed

memory modules.

Reseat the memory modules.

See "Troubleshooting System

Memory" on page 159.

Embedded NIC

x

and

NIC

y

:

OS NIC=

<ENABLED

|DISABLED>

,

Management

Shared NIC=

<ENABLED

|DISABLED>

The operating system NIC

interface is set in BIOS. The

Management Shared NIC

interface is set in

management tools.

Check the system

management software or the

System Setup program for

NIC settings. If a problem is

indicated, see

"Troubleshooting a NIC" on

page 153.

Message

Causes

Corrective Actions

book.book Page 41 Wednesday, December 18, 2013 2:48 PM

Advertising