Dell PowerEdge R815 User Manual

Page 32

Advertising
background image

32

About Your System

E1813 Internal Dual

SD Module

Card #

failed. Check

SD card.

The internal dual SD

module card failed.

Reseat the internal dual

SD module card.
If the problem persists,

see "Getting Help" on

page 185.

E1814 Internal SD

Module Card #

write-

protected.

Check SD

card.

The internal dual SD

module card is write-

protected and cannot be

used.

Change the write-protect

switch setting on SD card.

E1815 Internal Dual

SD Module

redundancy

lost. Check

SD cards.

The internal dual SD

module bootable media is

no longer redundant.

Reseat the internal dual

SD module card.
If the problem persists,

see "Getting Help" on

page 185.

E1A14 SAS cable A

failure.

Check

connection.

SAS cable A is missing or

bad.

Reseat the cable. If the

problem persists, replace

the cable.
If the problem persists,

see "Getting Help" on

page 185.

E1A15 SAS cable B

failure.

Check

connection.

SAS cable B is missing or

bad.

Reseat the cable. If the

problem persists, replace

the cable.
If the problem persists,

see "Getting Help" on

page 185

E1A1D Control panel

USB cable not

detected.

Check cable.

USB cable to the control

panel is missing or bad.

Reseat the cable. If the

problem persists, replace

the cable.
If the problem persists,

see "Getting Help" on

page 185.

Code

Text

Causes

Corrective Actions

book.book Page 32 Wednesday, December 18, 2013 2:48 PM

Advertising