Activating remote replication, Replication repository virtual disks – Dell POWERVAULT MD3600F User Manual

Page 186

Advertising
background image

186

Configuration: Premium Feature— Remote Replication

Activating Remote Replication

NOTE:

If you ordered the Remote Replication feature, you received a Premium

Feature Activation card in the Dell PowerVault MD storage array shipping box.

Follow the directions on the card to install and enable this feature.

After the Remote Replication feature is installed following the steps on the

Premium Feature Activation card, it must be activated using a wizard-based

process. As part of activation, the following actions occur:

• Two replication repository virtual disks are created using existing capacity

on either a disk group or storage array specified by the user.

• All hosts currently using the highest-numbered Fibre Channel host port

(Port 3) on each RAID controller are logged out.

• The highest-numbered Fibre Channel host port (Port 3) on each RAID

controller is reserved for replication data transmission.

• The highest-numbered Fibre Channel host port (Port 3) on each RAID

controller is not available to direct host access when the Remote

Replication premium feature is activated. Any attempted host

communication to this port is rejected.

• Communication between the replication-reserved Fibre Channel ports

requires established zoning of Fibre Channel switches in the fabric, see

"Required Switch Zoning Configurations" on page 190.

• Before establishing virtual disk replication pairs, the Remote Replication

premium feature must be activated on each of the storage arrays

participating in replication.

Replication Repository Virtual Disks

Using the Remote Replication premium feature on the storage array requires

that two replication repository virtual disks be created on one of the disk

groups on the storage array. The RAID controller module stores replication

information on these virtual disks, including information about incomplete

remote writes that can be used to recover from RAID controller module resets

and accidental storage array shutdown.

book.book Page 186 Tuesday, June 18, 2013 3:03 PM

Advertising
This manual is related to the following products: