Dell POWERVAULT MD3600F User Manual

Page 291

Advertising
background image

Troubleshooting: Your Storage Array Software

291

3 If you have an in-band storage array, use the following procedure. Click

Refresh after each step to check the results:

a

Ensure that the host context agent software is installed and running. If

the host is started before it is connected to the controllers in the

storage array, the host context agent software is not able to find the

controllers. If so, ensure that the connections are tight, and restart the

host context agent software.

b

Ensure that the network can access the host by using the ping

command in the following syntax:

ping <host-name-or-IP-address-of-the-host>

.

If the network can access the host, continue to step c. If the network

cannot access the host, go to step d.

c

Remove the host with the unresponsive status from the MDSM, and

add that host again.
If the host returns to optimal status, you have completed this procedure.

d

Ensure that the power to the host is turned on and that the host

is operational.

e

If applicable, ensure that the host bus adapters are installed in the

host.

f

Examine all external cables and switches or hubs to ensure that you

cannot see any damage and that they are tightly connected.

g

If you have recently replaced or added the controller, restart the host

context agent software so that the new controller is found.
If a problem exists, make the appropriate modifications to the host.

4 If you have an out-of-band storage array, use the following procedure. Click

Refresh after each step to ensure the results:

a

Ensure that the network can access the controllers by using the ping

command. Use the following syntax:

ping <controller-IP-address>

If the network can access the controllers, continue to step b. If the

network cannot access the controllers, go to step c.

book.book Page 291 Tuesday, June 18, 2013 3:03 PM

Advertising