Troubleshooting array cooling problems, On, see step 2 – Dell POWERVAULT MD3600F User Manual

Page 299

Advertising
background image

Troubleshooting: Your Array

299

CAUTION:

Power supply/cooling fan modules are hot-swappable. The array can

operate on a single power supply; however both modules must be installed to
ensure proper cooling. A single power supply/cooling fan module can be removed
from a powered-on array for a maximum period of 5 minutes. Beyond that time, the
array may automatically shut down to prevent damage.

2 Reseat the power supply by removing and reinstalling it. See "Power Supply

and Cooling Fan Features" on page 31.

NOTE:

After installing a power supply, allow several seconds for the array to

recognize the power supply and to determine if it is working properly.

If the problem is not resolved, see "Getting Help" on page 309.

Troubleshooting Array Cooling Problems

CAUTION:

Many repairs may only be done by a certified service technician.

You must only perform troubleshooting and simple repairs as authorized in
your product documentation, or as directed by the online or telephone service
and support team. Damage due to servicing that is not authorized by Dell is not
covered by your warranty. Read and follow the safety instructions that came
with the product.

Ensure that none of the following conditions exist:

• Array cover or drive blank is removed.
• Ambient temperature is too high. See “Technical Specifications” in the

Getting Started Guide.

• External airflow is obstructed.
• The power supply/cooling fan module is removed or has failed. See

"Troubleshooting Power Supply/Cooling Fan Module" on page 298.

If the problem is not resolved, see "Getting Help" on page 309.