Dell POWERVAULT MD3600F User Manual

Page 54

Advertising
background image

54

Planning: MD3600f Series Storage Array Terms and Concepts

Use either of the following methods to move disk groups and virtual disks:

• Hot virtual disk migration—Disk migration with the destination storage

array power turned on.

• Cold virtual disk migration—Disk migration with the destination storage

array power turned off.

NOTE:

To ensure that the migrating disk groups and virtual disks are correctly

recognized when the target storage array has an existing physical disk, use hot

virtual disk migration.

When attempting virtual disk migration, follow these recommendations:

• Moving physical disks to the destination array for migration—When

inserting drives into the destination storage array during hot virtual disk

migration, wait for the inserted physical disk to be displayed in MDSM

before inserting the next physical disk.

WARNING:

Without the delay between drive insertions, the storage array can

become unstable and manageability is temporarily lost.

• Migrating virtual disks from multiple storage arrays into a single storage

array—When migrating virtual disks from multiple or different storage

arrays into a single destination storage array, move all of the physical disks

from the same storage array as a set into the new destination storage array.

Ensure that all of the physical disks from a storage array are migrated to

the destination storage array before starting migration from the next

storage array.

NOTE:

If the drive modules are not moved as a set to the destination storage

array, the newly relocated disk groups may not be accessible.

• Migrating virtual disks to a storage array with no existing physical disks—

Turn off the destination storage array, when migrating disk groups or a

complete set of physical disks from a storage array to another storage array

that has no existing physical disks. After the destination storage array is

turned on and has successfully recognized the newly migrated physical

disks, migration operations can continue.

NOTE:

Disk groups from multiple storage arrays must not be migrated at the

same time to a storage array that has no existing physical disks.

book.book Page 54 Tuesday, June 18, 2013 3:03 PM

Advertising
This manual is related to the following products: