Dell PowerEdge C1100 User Manual

Page 22

Advertising
background image

22

About Your System

Table 1-7. System Identification Indicators

Table 1-8. Power Indicator Codes

Table 1-9. Fault Indicator Codes

System Identification Indicator

Condition

Steady blue

IPMI using chassis identify command on or

ID button press identification on.

Blinks blue blinking

Only IPMI using chassis identify command

blink on.

Blue off

IPMI using chassis identify command off or

ID button press identification off.

Power Indicator

Condition

Steady green

Power supply is on (AC OK/DC OK) or in

standby mode (90–264 VAC)

Steady yellow

Power supply faulty

(UVP/OVP/OCP/SCP/OTP/Fan Fault)

Yellow off

Power supply is off or AC input

voltage is out of normal operating range

(90 VAC–264 VAC)

Fault Indicator

Condition

Amber blinking

System failure
or
Non-critical failure: non-critical fan,

voltage, temperature state, or CPU thermal

trip.

Amber off

No system failure
or
Off

book.book Page 22 Tuesday, February 26, 2013 11:33 AM

Advertising