Post error codes – Dell PowerEdge C1100 User Manual

Page 23

Advertising
background image

About Your System

23

POST Error Codes

Code

Log in BMC Error Message

Corrective Action

0000

Yes

Timer Error

Remove AC power to the system for

10 seconds and restart the system.
If the problem persists, see "Getting

Help" on page 123.

0003

Yes

CMOS Battery Low See "Troubleshooting the System Battery"

on page 104.

0004

Yes

CMOS Settings

Wrong

Remove AC power to the system for

10 seconds and restart the system.
If the problem persists, see "Getting

Help" on page 123.

0005

Yes

CMOS Checksum

Bad

Remove AC power to the system for

10 seconds and restart the system.
If the problem persists, see "Getting

Help" on page 123.

000B

Yes

CMOS memory size

Wrong

Remove AC power to the system for

10 seconds and restart the system.
If the problem persists, see "Getting

Help" on page 123.

000C

Yes

RAM R/W test failed Remove AC power to the system for

10 seconds and restart the system.
If the problem persists, see "Getting

Help" on page 123.

000E

Yes

A: Driver Error

See "Troubleshooting a Hard Drive" on

page 109.

000F

Yes

B: Driver Error

See "Troubleshooting a Hard Drive" on

page 109.

0012

Yes

CMOS Date/Time

Not Set

Remove AC power to the system for

10 seconds and restart the system. See

"Troubleshooting the System Battery" on

page 104.
If the problem persists, see "Getting

Help" on page 123.

book.book Page 23 Tuesday, February 26, 2013 11:33 AM

Advertising