Table 1-18. BMC Watchdog Timer Commands (NETFUN: 06H, 07H)

Commands

NetFn

CMD

O/M

Supported

Reset Watchdog Timer
Set Watchdog Timer
Get Watchdog Timer

App
App
App

22H
24H
25H

M
M
M

Yes
Yes
Yes

Table 1-19. Chassis Commands (NETFUN: 00H, 01H)

Commands

NetFn

CMD

O/M

Supported

Get Chassis Capabilities

Chassis

00H

M

Yes

Get Chassis Status

Chassis

01H

M

Yes

Chassis Control

Chassis

02H

M

Yes

Chassis Reset

Chassis

03H

N

No

Chassis Identify

Chassis

04H

O

Yes

Set Front Panel Button
Enables

Chassis

0AH

N

No

Set Chassis Capabilities

Chassis

05H

N

No

Set Power Restore Policy

Chassis

06H

O

Yes

Set Power Cycle Interval

Chassis

0BH

O

Yes
(Default: 10 seconds)

Get System Reset Cause

Chassis

07H

N

No

Restart Cause
[3:0] AH = Soft reset
(e.g. CTRL-ALT-DEL)

Set System Boot Options

Chassis

08H

O

Yes

Get System Boot Options

Chassis

09H

O

Yes

Get POH Counter

Chassis

0FH

M

No

Table 1-20. Event Commands (NETFUN: 04H, 05H)

Commands

NetFn

CMD

O/M

Supported

Set Event Receiver
Get Event Receiver
Platform Event (“Event Message”)

S/E
S/E
S/E

00H
01H
02H

M
M
M

Yes
Yes
Yes

Advertising