Using the Baseboard Management Controller
Table 1-29. Dell OEM Commands (NETFUN: 2EH, 2FH)
Commands
NetFn
CMD
Request and Response
OemSetUbootEthaddr
OEM
21H
This command is for Dedicated-NIC.
After issuing the OEM command, user
must reset BMC manually.
REQUEST:
Byte 1–17: MAC address
Byte 18: End data — must be 00H
RESPONSE:
Byte 1 — Completion code
OemSetUbootEth1addr
OEM
23H
This command is for Shared–NIC. After
issuing the OEM command, user must
reset BMC manually.
REQUEST:
Byte 1–17: MAC address
Byte 18: End data — must be 00H
RESPONSE:
Byte 1 - Completion code
OemGetBMCSKU
OEM
75H
REQUEST:
REQUEST:
Byte 1–17: MAC address
Byte 18: End data — must be 00H
RESPONSE:
Byte1 – Completion code
Byte2 – BMC SKU
00h AST2050
01h AST1100