Sensor summary – Dell PowerEdge C6100 User Manual

Page 41

Advertising
background image

41

Using the Baseboard Management Controller

2Ah

FCB Ambient1 Temperature (01h)

Threshold (01h)

2Bh

FCB Ambient2

ww

w

.

de

l

l

. co

m

|

s

u

pp

o

rt

. d

e

ll

. c

o

m

Table 1-42. Entity ID and Instance Table

Entity ID

Entity Instance

Entity Name

Sensor Numbers

01h

PS Current

A1h

02h

PSU 1 POUT

A3h

0Ah (Power Supply)

03h

PSU 2 POUT

A4h

08h

PSU 1 Present

A6h

09h

PSU 2 Present

A7h

Sensor Summary

In the Offset column:
AM = Assertion
mask

DM = Deassertion mask

RM = Reading mask
SC = Sensor capabilities
SI = Sensor initialization
TM = Settable/Readable threshold mask

Table 1-43. Sensor Summary

Sensor
Number

Sensor Name

Sensor Type

Event/Reading Type

Offset

21h

MLB TEMP1

Temperature (01h)

Threshold (01h)

SI: 7Fh

22h

MLB TEMP 2

23h

MLB TEMP 3


61h

Processor 1

Temp

62h

Processor 2

Temp

SC: E8h

AM:

0A80h DM:

7A80h TM:

3838h

Temperature (01h)

Threshold (01h)

SI: 7Fh SC:

E8h AM:

0A80h DM:

7A80h TM:

3838h

SI: FCh SC:

E8h AM:

0200h DM:

2000h TM:

3030h

Advertising