Using the Baseboard Management Controller

Table 1-48. Threshold Settings and Converting Formulas

Sensor
Number

Sensor Name

The Converting Formula

Upper non-
recoverable

Upper
critical

Upper
non-critical

Lower non-
recoverable

Lower
critical

Lower
non-critical

52h

VCORE 2

Actual_Reading (Volts) = Raw_Data x 0.0116

0xFF

0xFF

0xFF

0x00

0x00

0x00


Temperature
21h

MLB TEMP 1

Actual_Reading (degrees C) = Raw_Data

0x5A

0x57

0x55

0x00

0x00

0x00


22h

MLB TEMP 2

Actual_Reading (degrees C) = Raw_Data

0x5A

0x57

0x55

0x00

0x00

0x00


23h

MLB TEMP 3

Actual_Reading (degrees C) = Raw_Data

0x5A

0x57

0x55

0x00

0x00

0x00


61h

Processor 1 Temp Actual_Reading (degrees C) = Raw_Data

0x5A

0x55

0x51

0x00

0x00

0x00


62h

Processor Temp 2 Actual_Reading (degrees C) = Raw_Data

0x5A

0x55

0x51

0x00

0x00

0x00


2Ah

FCB Ambient1 Actual_Reading (degrees C) = Raw_Data

0xFF

0x32

0x00

0x00

0x00

0x00


2Bh

FCB Ambient2 Actual_Reading (degrees C) = Raw_Data

0xFF

0x32

0x00

0x00

0x00

0x00

Advertising