Threshold Settings and Converting Formulas

Table 1-47. Threshold Settings and Converting Formulas

Sensor
Number

Sensor Name

The Converting Formula


Fan

Upper non-
recoverable

Upper
critical

Upper
non-critical

Lower non-
recoverable

Lower
critical

Lower
non-critical

01h

FCB FAN1

Actual_Reading (RPM) = Raw_Data x 100

0xFF

0xFF

0xFF

0x00

0x0F

0x00


02h

FCB FAN2

Actual_Reading (RPM) = Raw_Data x 100

0xFF

0xFF

0xFF

0x00

0x0F

0x00


03h

FCB FAN3

Actual_Reading (RPM) = Raw_Data x 100

0xFF

0xFF

0xFF

0x00

0x0F

0x00


04h

FCB FAN4

Actual_Reading (RPM) = Raw_Data x 100

0xFF

0xFF

0xFF

0x00

0x0F

0x00


Voltage
14h

PS 12V

Actual_Reading (Volts) = Raw_Data x 0.062

0xD8

0xD4

0xCF

0xAB

0xAF

0xB4


15h

PS 5V

Actual_Reading (Volts) = Raw_Data x 0.026

0xD7

0xD3

0xCD

0xA9

0xAE 0xB3


16h

STBY 3.3V

Actual_Reading (Volts) = Raw_Data x 0.0172

0xD6

0xD3

0xCD

0xA9

0xAD 0xB3


51h

VCORE 1

Actual_Reading (Volts) = Raw_Data x 0.0083

0xFF

0xFF

0xFF

0x00

0x00

0x00