Using the Baseboard Management Controller

Table 1-46. Sensor Summary

Sensor
Number

Sensor Name

Sensor Type

Event/Reading Type

Offset

A3h

PSU 1 POUT

Current (03h)

Threshold (01h)

SI: C0h

A4h

PSU 2 POUT

SC: C0h

AM: 0000h
DM: 0000h
TM: 0000h

A5h

PCI BUS

Critical Interrupt (13h)

Sensor-specific (6Fh) SI: 63h

SC: 40h

AM:

0030h DM:

0000h RM:

0030h

A6h

PSU 1 Present

Power Supply (08h)

Sensor-specific (6Fh) SI: 60h

A7h

PSU 2 Present

SC: 40h

AM:

0040h DM:

0001h RM:

0003h

A8h

PSU 1 AC Status Power Unit (09h)

Sensor-specific (6Fh) SI: 60h

A9h

PSU 2 AC Status




18h

NM Exception DCh

72h


19h

NM Health

DCh

73h


1Ah

NM Capabilities DCh

74h


1Bh

NM Threshold DCh

72h

SC: 40h

AM: 0010h

DM: 0010h

RM: 0011h

C0h

No sensor name

(NM Discovery)

00h

00h