Troubleshooting a damaged system – Dell PowerEdge 2900 User Manual

Page 121

Advertising
background image

Troubleshooting Your System

121

4 Let the system dry thoroughly for at least 24 hours.
5 Close the system. See "Closing the System" on page 53.
6 Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.

If the system does not start properly, see "Getting Help" on page 147.

7 If the system starts properly, shut down the system and reinstall all of the expansion cards that you

removed. See "Installing an Expansion Card" on page 68.

8 Run the appropriate online diagnostic test. See "Using Server Administrator Diagnostics" on page 135.

If the tests fail, see "Getting Help" on page 147.

Troubleshooting a Damaged System

Problem

System was dropped or damaged.

Action

CAUTION:

Only trained service technicians are authorized to remove the system cover and access any of the

components inside the system. Before performing any procedure, see your Product Information Guide for
complete information about safety precautions, working inside the computer and protecting against electrostatic
discharge.

1 Open the system. See "Opening the System" on page 53.
2 Ensure that the following components are properly installed:

Expansion cards

Power supplies

Fans

Processors and heat sinks

Memory modules

Drive-carrier connections to the SAS backplane board, if applicable

3 Ensure that all cables are properly connected.
4 Close the system. See "Closing the System" on page 53.
5 Run the system board tests in the system diagnostics. See "Running the System Diagnostics" on

page 135.

If the tests fail, see "Getting Help" on page 147.

Advertising