Table 1-6 lists the lcd status messages that can – Dell PowerEdge 2900 User Manual

Page 19

Advertising
background image

About Your System

19

Table 1-6.

LCD Status Messages

Code

Text

Causes

Corrective Actions

N/A

SYSTEM NAME

A 62-character string that can be
defined by the user in the System
Setup program.

The SYSTEM NAME displays
under the following conditions:

• The system is powered on.
• The power is off and active

POST errors are displayed.

This message is for information
only.

You can change the system string
in the System Setup program. See
"Using the System Setup
Program" on page 35.

E1000

FAILSAFE, Call

Support

See "Getting Help" on page 147.

E1114

Temp Ambient

Ambient system temperature is
out of acceptable range.

See "Troubleshooting System
Cooling Problems" on page 123.

E1116

Temp Memory

Memory has exceeded acceptable
temperature and has been
disabled to prevent damage to the
components.

See "Troubleshooting System
Cooling Problems" on page 123.

E1210

CMOS Batt

CMOS battery is missing, or the
voltage is out of acceptable range.

See "Troubleshooting the System
Battery" on page 122.

E1211

ROMB Batt

RAID battery is either missing,
bad, or unable to recharge due to
thermal issues.

Reseat the RAID battery. See
"Replacing the SAS RAID
Controller Daughter Card
Battery" on page 96, an
d
"Troubleshooting System Cooling
Problems" on page 123.

E12

nn

XX

PwrGd

Specified voltage regulator has
failed.

See "Getting Help" on page 147.

E1229

CPU # VCORE

Processor # VCORE voltage
regulator has failed.

See "Getting Help" on page 147.

E1310

RPM Fan ##

RPM of specified cooling fan is
out of acceptable operating range.

See "Troubleshooting System
Cooling Problems" on page 123.

E1313

Fan Redundancy

The system is no longer fan-
redundant. Another fan failure
will put the system at risk of over-
heating.

Check control panel LCD for
additional scrolling messages. See
"Troubleshooting System Cooling
Problems" on page 123.