Dell PowerEdge 2900 User Manual

Page 23

Advertising
background image

About Your System

23

E1A14

SAS Cable A

SAS cable A is unseated, missing,
or bad.

Check the cable connection to
the SAS backplane. See "Cabling
the SAS Backplane Boards" on
page 99.

E1A15

SAS Cable B

SAS cable B is unseated, missing,
or bad.

Check the cable connection to
the SAS backplane. See "Cabling
the SAS Backplane Boards" on
page 99.

E1A16

SAS Cable FB

Flex bay SAS cable is unseated,
missing, or bad.

Check the cable connection to
the SAS backplane. See "Cabling
the SAS Backplane Boards" on
page 99.

E1A17

Pwr Cable FB

Flex bay power cable is unseated,
missing, or bad.

Check the power cable
connection to the flex bay
backplane. See "Installing the 1x2
Flex Bay Drive Bracket" on
page 95.

E1A18

PDB Ctrl Cable

The power distribution board
control cable is unseated,
missing, or bad.

Ensure that the power
distribution board control cable is
seated properly. If the problem
persists, replace the power
distribution board control cable.
See "Installing the Power
Distribution Board" on page 112.

E2010

No Memory

No memory is installed in the
system.

Install memory. See "Memory" on
page 82.

E2011

Mem Config Err

Memory detected, but is not
configurable. Error detected
during memory configuration.

See "Troubleshooting System
Memory" on page 124.

E2012

Unusable Memory

Memory is configured, but not
usable. Memory subsystem
failure.

See "Troubleshooting System
Memory" on page 124.

E2013

Shadow BIOS Fail

The system BIOS failed to copy
its flash image into memory.

See "Troubleshooting System
Memory" on page 124.

E2014

CMOS Fail

CMOS failure. CMOS RAM not
functioning properly.

See "Getting Help" on page 147.

E2015

DMA Controller

DMA controller failure.

See "Getting Help" on page 147.

E2016

Int Controller

Interrupt controller failure.

See "Getting Help" on page 147.

Table 1-6.

LCD Status Messages (continued)

Code

Text

Causes

Corrective Actions