Dell PowerEdge 2900 User Manual

Page 22

Advertising
background image

22

About Your System

E1712

PCI SERR B## D##

F##

PCI SERR Slot #

The system BIOS has reported a
PCI system error on a component
that resides in PCI configuration
space at buss ##, device ##,
function ##.

The system BIOS has reported a
PCI system error on a component
that resides in slot #.

Remove and reseat the PCI
expansion cards. If the problem
persists, see "Troubleshooting
Expansion Cards" on page 131.

If the problem persists, the
system board is faulty. See
"Getting Help" on page 147.

E1714

Unknown Err

The system BIOS has determined
that there has been an error in the
system, but is unable to
determine its origin.

See "Getting Help" on page 147.

E171F

PCIE Fatal Err

B## D## F##

PCIE Fatal Err

Slot #

The system BIOS has reported a
PCIe fatal error on a component
that resides in PCI configuration
space at bus ##, device ##,
function ##.

The system BIOS has reported a
PCIe fatal error on a component
that resides in slot #.

Remove and reseat the PCI
expansion cards. If the problem
persists, see "Troubleshooting
Expansion Cards" on page 131.

If the problem persists, the
system board is faulty. See
"Getting Help" on page 147.

E1810

HDD ## Fault

The SAS subsystem has
determined that hard drive ##
has experienced a fault.

See "Troubleshooting a Hard
Drive" on page 129.

E1811

HDD ## Rbld Abrt

The specified hard drive has
experienced a rebuild abort.

See "Troubleshooting a Hard
Drive" on page 129. If the
problem persists, see your RAID
documentation.

E1812

HDD ## Removed

The specified hard drive has been
removed from the system.

Information only.

E1913

CPU & Firmware

Mismatch

The BMC firmware does not
support the CPU.

Update to the latest BMC
firmware. See the BMC User’s
Guide for more information on
setup and use of BMC.

E1A10

PBD Pwr Cable

The power distribution board
power cable is unseated, missing,
or bad.

Ensure that the power
distribution board power cable is
seated properly. If the problem
persists, replace the power
distribution board power cable.
See "Installing the Power
Distribution Board" on page 112.

Table 1-6.

LCD Status Messages (continued)

Code

Text

Causes

Corrective Actions

Advertising