Dell PowerVault NX3500 User Manual

Page 23

Advertising
background image

About Your Solution

23

Table 1-3. LCD Status Messages

Code

Text

Causes

Corrective Actions

E1000

Failsafe

voltage error.

Contact

support.

Check the system event

log for critical failure

events.

Remove AC power to the

system for 10 seconds and

restart the system.
If the problem persists,

see "Getting Help" on

page 113.

E1114

Ambient Temp

exceeds

allowed range.

Ambient temperature has

reached a point outside of

the allowed range.

See "Troubleshooting

System Cooling

Problems" on page 96.

E1116

Memory

disabled, temp

above range.

Power cycle

AC.

Memory has exceeded

allowable temperature and

has been disabled to

prevent damage to the

components.

Remove AC power to the

system for 10 seconds and

restart the system.
See "Troubleshooting

System Cooling

Problems" on page 96.

If the problem persists,

see "Getting Help" on

page 113.

E1210

Motherboard

battery

failure. Check

battery.

CMOS battery is missing

or the voltage is outside of

the allowable range.

See "Troubleshooting the

System Battery" on

page 95.

E1211

RAID

Controller

battery

failure. Check

battery.

RAID battery is either

missing, bad, or unable to

recharge due to thermal

issues.

Reseat the RAID battery

connector. See

"Troubleshooting System

Cooling Problems" on

page 96.

E1216

3.3V Regulator

failure.

Reseat PCIe

cards.

3.3 V voltage regulator has

failed.

Remove and reseat the

PCIe expansion cards.

If the problem persists,

see "Troubleshooting an

Expansion Card" on

page 101.

book.book Page 23 Monday, January 24, 2011 12:24 PM

Advertising