Dell PowerVault NX3500 User Manual
Page 26

26
About Your Solution
E141F
CPU # protocol
error. Power
cycle AC.
The system BIOS
has reported a processor
protocol error.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
E1420
CPU Bus parity
error. Power
cycle AC.
The system BIOS has
reported a processor bus
parity error.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
E1422
CPU # machine
check error.
Power
cycle AC.
The system BIOS has
reported a machine
check error.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
E1610
Power Supply #
(### W)
missing.
Check power
supply.
Specified power supply
was removed or is missing
from the system.
E1614
Power Supply #
(### W) error.
Check power
supply.
Specified power supply
has failed.
E1618
Predictive
failure on
Power Supply #
(### W).
Check PSU.
An over-temperature
condition or power supply
communication error has
caused the predictive
warning of an impending
power supply failure.
Table 1-3. LCD Status Messages
(continued)
Code
Text
Causes
Corrective Actions
book.book Page 26 Monday, January 24, 2011 12:24 PM