Dell PowerVault NX3500 User Manual

Page 36

Advertising
background image

36

About Your Solution

Table 1-4. System Messages

Message

Causes

Corrective Actions

Alert! iDRAC6 not

responding.

Rebooting.

The iDRAC6 is not

responding to BIOS

communication either

because it is not functioning

properly or has not

completed initialization.

The system will reboot.

Wait for the system to

reboot.

Alert! iDRAC6 not

responding.

Power required

may exceed PSU

wattage.

Alert!

Continuing

system boot

accepts the risk

that system may

power down

without warning.

The iDRAC6 has hung.
The iDRAC6 was remotely

reset while system was

booting.
After AC recovery, the

iDRAC6 takes longer than

normal to boot.

Remove AC power to the

system for 10 seconds and

restart the system.

Alert! Power

required exceeds

PSU wattage.

Check PSU and

system

configuration.

Alert!

Continuing

system boot

accepts the risk

that system may

power down

without warning.

The system configuration

of processor,

memory modules,

and expansion cards may

not be supported by the

power supplies.

If any system components

were just upgraded,

return the system to the

previous configuration.

If the system boots without

this warning, then the

replaced component(s) are

not supported with this

power supply. If Energy

Smart power supplies are

installed, replace them with

High Output power supplies

to use the components.

See "Power Supplies" on

page 77.

book.book Page 36 Monday, January 24, 2011 12:24 PM